Dongguan Lixian Instrument Scientific Co.,LTD

Dongguan Lixian Instrument Scientific Co.,LTD have 22 years of experience in design, research and development. Factory covers an area of 6000 square meters, Total number of employees more than 60 in

Manufacturer from China
Active Member
3 Years
Home / Products / Wine Cellar Air Conditioners /

2 3 5 6 8 9 10P Three Phase Air Conditioner Humidity Setting Range 45-65%±5%

Contact Now
Dongguan Lixian Instrument Scientific Co.,LTD
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:Mrliang
Contact Now

2 3 5 6 8 9 10P Three Phase Air Conditioner Humidity Setting Range 45-65%±5%

Ask Latest Price
Video Channel
Brand Name :Taikang
Model Number :Model G50TH G71TH L125TH L150TH L150TH2 L200TH L225TH L250TH
Certification :CE
Place of Origin :China
MOQ :1
Price :negotiate
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :negotiate
Delivery Time :7 days
Packaging Details :wood
Model :G50TH G71TH L125TH L150TH L150TH2 L200TH L225TH L250TH
Type :PTC electric heater
Temperature setting range and control accuracy :18~25℃±1℃
Humidity setting range and control accuracy :45~65%±5%
Evaporator :Copper tube finned
power :Three-phase380V/~/50Hz
Refrigerant :R410A
control accuracy :±5-10%.
number of p :2 3 5 6 6 8 9 10 P
items :cabinet type (combined) frequency conversion constant temperature and humidity
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Wine Cellar Air Conditioners Humidity Setting Range And Control Accuracy 45~65%±5% 2,3,5,6,8,9,10 P

Wine Cellar Air Conditioner is used for indoor air conditioning under various environmental conditions, and has multiple functions such as cooling, dehumidification, heating, humidification, and ventilation. Temperature control range: when the temperature is set at 18-25°C, the control accuracy is ±0.5-1°C, the relative humidity is set at 50-70%, and the control accuracy is ±5-10%.

Wine Cellar Air Conditioner Cooling principle:

When the refrigeration system is working, the high-temperature and high-pressure R410 gas discharged from the compressor enters the condenser and is condensed into a medium-temperature supercooled liquid. After being throttled and depressurized by the expansion valve, it becomes a low-temperature and low-pressure gas-liquid two-phase mixture and enters the evaporator. It evaporates and absorbs the heat of the air passing through the evaporator, so that the air flowing through the evaporator can be cooled. After vaporization, the steam is sucked by the compressor, so that the cycle is continuous, so as to achieve the purpose of cooling.

Factory Air Conditioner Dehumidification principle:

Since the surface temperature of the fins of the evaporator is lower than the dew point temperature of the air, when the air flows through the surface of the evaporator, water will precipitate on the surface of the evaporator.

Heating: start the heater, when the air flows through the heater, the air is heated and the temperature rises.

Humidification: Start the humidifier, and the water vapor generated by the humidifier is continuously sent into the room by the fan to achieve the purpose of humidification..

Factory Air Conditioner Application

The unit has a variety of models to choose from, and can be widely used in the air conditioning needs of electronic factories, hospitals, pharmaceutical factories, printing factories, post and telecommunications, banks, computer rooms, power supply and distribution stations, communication stations and other buildings.

Technical Parameters

items Hanging constant temperature and humidity cabinet type (combined) frequency conversion constant temperature and humidity
Model Indoor Unit G50TH G71TH L125TH L150TH L150TH2 L200TH L225TH L250TH
outdoor unit

TK-WB

TK71WB TK-125WB TK-150WB TK-150WB TK200WB TK225WB TK250WB
number of p P 2 3 5 6 6 8 9 10
Cooling capacity kW 5 7.1 12.5 15 15 20 22.5 25
Electric heating kW 7.5 15 23.4 28 28 36 41 47
indoor unit air volume m3 / h 1150 1700 2500 3600 3500 5000 5000 5400
External residual pressure Pa 50/0 50/0 50/0 60/0 80/0 80/0 80/0 80/0
noise dB(A) 52/54 54/56 58/60 58/60 58/60 62/64 62/64 62/64
Temperature setting range and control accuracy 18~25℃±1℃
Humidity setting range and control accuracy 45~65%±5%