Dongguan Lixian Instrument Scientific Co.,LTD

Dongguan Lixian Instrument Scientific Co.,LTD have 22 years of experience in design, research and development. Factory covers an area of 6000 square meters, Total number of employees more than 60 in

Manufacturer from China
Active Member
3 Years
Home / Products / Laboratory Testing Machines /

ISO 9239-1 Building Material Fire Tester ASTM E648 Critical Radiant Flux With Radiant

Contact Now
Dongguan Lixian Instrument Scientific Co.,LTD
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:Mrliang
Contact Now

ISO 9239-1 Building Material Fire Tester ASTM E648 Critical Radiant Flux With Radiant

Ask Latest Price
Video Channel
Brand Name :lixian
Model Number :HZ-Building Material Fire Tester-15
Certification :CE
Place of Origin :CHINA
MOQ :1
Price :negotiate
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :500hundred sets per month
Delivery Time :7 work days
Packaging Details :wooden
PRODUCT NAME :Building Material Fire Tester
POWER :220V 50HZ
MATERIAL :Stainless Steel
HEAT FLUX METER ACCURACY :± 0.2Kw / M2
HEAT FLUX MEASUREMENT RANGE :RANGE: (0-15) Kw / M2
USAGE :Critical Radiant Flux Test
HIGH LIGHT :ignitability test, microscale combustion calorimeter
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Building Material Fire Tester ISO 9239-1 ASTM E648 Fire Tester Critical Radiant Flux With A Radiant Heat Energy Source

Description:
FLOORING RADIANT PANEL TEST (CRITICAL RADIANT FLUX), ASTM E 648, NFPA 253, FED. STD. NO. 372, NBSIR 75-950: The Floor Radiant Panel apparatus involves a horizontally mounted floor covering test sample which receives radiant energy from a gas-air fueled radiant panel mounted above one end of the sample and inclined at an angle of 30o. The radiant panel generates a radiant flux profile along the length of the sample ranging from a maximum of 1.1 W/cm2 immediately under the panel to approximately 0.1 W/cm2 at the end of the test sample. A gas fired pilot burner is used to initiate the ignition in the sample. The distance the flooring system burns to extinguishment is converted to watts per square centimeter (W/cm2) and is reported as critical radiant flux (CRF). This is the minimum radiant energy a fire needs to sustain flame propagation in the flooring system. In this test, a higher number indicates a more flame-resistant system; i.e., 0.45 W/cm2 is better than 0.22 W/ cm2.
Standard:
GB / T11785 "flooring combustion performance measurement - a radiant heat source”
ISO9239-1:2002 “flooring combustion performance Part 1-the combustion performance is determined with radiant heat resource”
ASTM E648:Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat
ASTM E970:Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
NFPA 253:Standard Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source
Parameter:

1. Power supply:AC 220V,50HZ;
2. Total power:2KW;
3. Timer: timing accuracy < 1s/h;
4. Heat flux measurement range: (0-15) Kw / m2;
5. Heat flux meter accuracy: ± 0.2Kw / m2;
6. Heat flux meter accuracy: <± 3%;
7. Thermal radiation temperature measurement range: 400-600 ℃, accuracy ± 0.5 ℃;
8. Blackbody temperature error: ± 5 ℃;
9. Exhaust speed: (2.5 ± 0.2) m / s;
10. Exhaust capacity: (39-85) m3 / min;
11. Porous refractory radiant panel size: 300mm × 450mm, about 900 ℃ high temperature capability;
12. Thermocouple: K diameter stainless steel sheathed thermocouple of 3.2mm;
13. Heat flux distribution requirements: at 200mm : (9.1 ± 0.4) KW / m2;
at 400mm : (5.0 ± 0.4) KW / m2;
at 600mm : (2.4 ± 0.2) KW / m2;
14. Combustion gases: propane (Customer);
15. Combustion gas flow rate: (0.026 ± 0.002) L / S;
16. Combustion burner: outer diameter ¢ 10mm inner diameter ¢ 6mm, burner tube hit 35 ¢ 0.7mm hole;
17. Flame height: 60 ~ 120mm adjustable;
18. Ignition system: high-voltage electronic ignition;
19. Powerful exhaust system: This machine is equipped with a powerful exhaust fan, when the test is completed, the system will start the exhaust fan exhaust outside.


Specification:

1. The apparatus is made of combustion chamber and control box;
2. Combustion chamber size: L1420 * W1200 * H2300 (mm);
3. Outline dimension:L2530*W1270*H2700mm(including electric cabinet);
4. Control box / combustion chamber material: high quality (t = 1.2mm) 304 is stainless steel, CNC machining, circular nice shape;
5. Blowtorch: made by our company, 304 stainless steel material, in full compliance with GB / T11785 standards;
6. Other mechanical parts are made of 304 stainless steel or A3 material thicker plating, anti-corrosion and rust.